Our products

Products

IP-BASED ROOM THERMOMETER WITH POE ETHERNET CONNECTION

spai60

Downloads:

spai60

• Ambient temperature (wall-mounted)
– Built-in temperature sensor
• Remote sensor input option – up to 4 inputs for PT100 or PT1000 probes
• Communication:
– Modbus TCP, 6 simultaneous connections
– Embedded web server, SNMP
– Alarm email notifications, SMTP protocol
• Measurement logging (Excel format) and curve display on web server
• Power over Ethernet (PoE) via Ethernet switch
• Measurement display (LCD)
• Applications: Cleanrooms, calibration laboratories, museums and exhibition halls, cleanrooms, data centers, warehouses.
The SPAi60 is a multi-channel thermometer designed for monitoring and traceability applications in controlled-atmosphere rooms
. This probe enables the retrieval of measurements via the Modbus/TCP
or SNMP protocols, the sending of alarms via email, and the autonomous saving of data to Excel files.

AMBIENT AND CONTACT TEMPERATURE SENSOR

spai

Downloads:

spai-spae-spc

For INDOOR and OUTDOOR use

SPAI-CAL: Indoor ambient temperature sensor
SPAE-CAL: Weatherproof outdoor ambient temperature sensor (IP65)
SPAI-A: With LCD display
SPAE-CNL/H: Weatherproof outdoor ambient temperature sensor (IP65) with HART protocol converter
SPC01-CAL: Contact probe (piping)

• 2-wire technology (4–20 mA) 12–35 V power supply

These sensors measure the ambient temperature of a room and provide a 4–20 mA output signal using two-wire technology. The measuring element (PT 100 platinum resistance sensor) ensures excellent measurement repeatability.
The indoor versions, which are compact and aesthetically pleasing, integrate seamlessly
(wall mounting).
The outdoor versions (waterproof) ensure excellent reliability in harsh environments.
The contact version is particularly well-suited for measuring temperature on piping (thanks to its aluminum base).

WATER LEVEL CONTROL RELAY

rnl35l

Downloads:

snl - rnl35l

For Resistive Level Sensors Type: SNL
• Multi-level sensor for conductive liquids.
Fully static. Up to 5 levels (electrodes with adjustable length).
Maximum pressure 6 bar.
Maximum temperature 150°C (high-temperature version).
IP 66-rated, cable outlet or connection head; Teflon-coated electrodes with 316L stainless steel tips.

• Application
Level control or regulation
For tanks, reservoirs, or channels ….
Fluid presence/absence detection
(leak detection, empty pipe detection, pump control).

Resistive level sensor, based on changes in electrical resistance caused by the presence of fluid
between two electrodes. This resistance is converted into a binary signal using a level relay.

The sensor operates on the principle of conductivity between a common
electrode and one or more switching-level electrodes. The
presence of a liquid is detected by a change in resistance at the
contact point of the electrode.

WIRELESS ACQUISITION FOR SILO TEMPERATURE PROBE

silogrid

Downloads:

silogrid

Silogrid: mesh network radio frequency temperature measurement system for silo thermometry applications
• Maximum reliability
– Mesh networking of all sensors
– Each probe acts as a relay
– Up to 8 hops possible to reach the receiver
– Dynamic reconfiguration based on the environment
– Transmission rate > 99.999%
• Optimal battery life: Over 3 years with AA (LR06) batteries
• Universal radio module – compatible with all sensors on the market: CTN, PT1000, etc., and digital sensors

• Description: SILOGRID is a robust and reliable wireless network designed for industrial environments
where interference can significantly degrade network performance.
Silogrid is based on proven wireless mesh network technology—SmartMesh® from Dust Networks®—and uses
the unlicensed 2.4 GHz band for transmission.

AIR DUCT THERMO-HYGROMETER

Downloads:

shl18

• SHL18-mA: Hygrometer with 4–20 mA output, 2-wire configuration
• SHL18-v: Hygrometer with 0–10 V output
• SHL18T-v: Thermo-hygrometer with 2 outputs (0–10 V)
• Usage
Measurement of relative humidity and ambient temperature,
Measurement of humidity and temperature in air ducts
Measurement of humidity and temperature in ovens or sterile chambers
Mounting via P-clamp or sliding flange
Rugged ambient or duct thermo-hygrometer for use in harsh environments
(contaminated atmosphere). The fully digital measurement concept ensures very high repeatability
as well as excellent long-term performance in cost-sensitive applications.

DUST REMOVAL AND CLEANING SEQUENCER

seq165

Downloads:

seq165

• 16 relay outputs with 250V – 6A breaking capacity
• Programmable cycle: automatic, timed, or manual
• Application: Dust removal valve, cleaning control box
• ATEX dust zone 21 and 22 option:Enclosed in a cabinet, certified assembly: II 2 D Ex tb IIIC T80°C Db
The SEQ165 sequencer is a programmable device designed for the sequential control of dust extraction valves
in cleaning cabinets; the display allows for quick diagnosis of proper
operation (checking the status of outputs, displaying various times).

IP-Based Room Thermohygrometer with Ethernet POE Connection

Downloads:

sai60

• Ambient temperature and humidity
• Barometer (atmospheric pressure) or relative pressure input
• Measurement logging and export (Excel format) and display of graphs on a web server
• Communication:
– Modbus TCP (Ethernet) 6 simultaneous connections
– Embedded web server
– SNMP
– Sending alarm emails, SMTP protocol
• Power supply via Ethernet Switch Power over Ethernet (PoE)
• High-brightness measurement display (OLED)
• Configurable audible alarm via internal buzzer
• Applications:
– Cleanrooms, calibration laboratories
– Museums and exhibition halls
– Cleanrooms, data centers, warehouses
– Air-conditioned rooms, ambient sensor
• Remote sensor option
– Humidity and temperature via cable up to 10 meters
The SAi60 is an ambient sensor designed for control and traceability applications in controlled-atmosphere rooms
. Connected to the Ethernet network, this sensor allows for the retrieval of measured data
via Modbus/TCP or SNMP protocol and the sending of alarm emails.

Ruggedized Ambient Temperature Sensor for Harsh Environments

Downloads:

sad120

• Built-in sensors:
• Temperature (-40°C to +85°C)
• Humidity (0–100%)
• Barometer (500–1150 hPa)
• Dew point (calculated)
• Remote dust sensor (0.1–0.5 mg/m³)
• Communication – RS485 half-duplex, Modbus RTU protocol
• Power supply: – 24V DC
• IP66-rated painted aluminum housing:
– wall mounting (optional DIN rail adapter)
– rugged M12 5-pin connector (RS485, power supply)
• 4-line, 16-character LCD display (temperature, humidity, atmospheric pressure, dust, or velocity)

The SAD120 is a room sensor designed for harsh environments. It is ideal for traceability applications or for monitoring the atmosphere in controlled-
s. This sensor allows measurements to be read via Modbus (RS485).

VOLTAGE PRESENCE RELAY

Downloads:

rpt23

Compatible with capacitive dividers, transformers, and AC/DC resistive bridges
• AC and DC voltage monitoring TRMS measurement: 10 ……600Vac, 1200Vdc (1600Vdc)
Voltage presence and absence thresholds for single-phase, three-phase, or DC networks
• Direct measurement, capacitive divider, or transformer High input impedance
compatible with neon indicators at the capacitive divider output
• Voltage and fault display for quick diagnostics
• Configuration Pushbutton under the swivel front panel
• Power supply: Universal 20….265Vac-dc or 100….400Vac-dc
• SIL2 option according to IEC 61508

The RPT23 relay, when used in conjunction with a capacitive divider, for example, monitors the presence or absence of AC voltage
on a medium- or high-voltage network. It can be used to signal a change in the network's status.

THERMAL PROTECTION RELAY

Downloads:

rps23

• All types of protection curves: constant-time, inverse-time, very inverse-time, or extremely inverse-time…
• 1, 2, 3, or 4 relay outputs
• Measurement display (10,000 points) with front-panel programming
• 1 or 2 isolated analog outputs with optional measurement converter function
• Universal power supply
• SIL2 option according to IEC 61508

The RPS23 is a universal thermal protection relay for direct current; when used with a standard shunt
(available as an option), it can measure any current. All protection coefficients
are freely adjustable by the user, allowing it to accommodate all types of loads. Optionally, the RPS23