Our products

Products

Compression fitting

Downloads:

Compression fitting

In many applications, a thermocouple or resistance probe must be equipped with mounting accessories such as flanges, fittings, or clamps to ensure optimal performance. Depending on the environments in which measurements will be taken, the materials used for the accessories may vary: – for sliding or non-sliding flanges, the most commonly used materials are generally stainless steel, steel, and PVDF; – for sliding fittings, the most commonly used materials are generally stainless steel, steel, and PVDF. The rings can be made from the same materials but also from materials such as PTFE and nickel-plated brass. – For counterflanges, they are supplied in cast iron, unless otherwise specified by the customer. Clamps are mounting accessories made of stainless steel, specifically designed for the food industry. As with all other accessories, we carefully evaluate any request for production in non-standard materials.

Average temperature sensors

Downloads:

Average temperature sensors

Probe designed to measure an average temperature over a long length. • Application: air duct temperature. Excellent temperature uniformity due to the thermal conductivity of the copper duct. Available in long lengths (> 20 meters), 10 mm diameter, 1 mm wall thickness, deformable sheath (annealed copper). Temperature range: -40°C … +85°C. Extended range available upon request.(250°C max) Mounted with a sliding oval clamp for quick and easy adjustment of the sensor to the process. Output via DAN aluminum head (epoxy-coated), IP65-rated. Connection via 3-point screw-type ceramic terminal block. (built-in signal converter option) Measurement element equivalent to PT100 Class B, 3-wire configuration.

Compost sensors

Downloads:

COMPOST

Compost probe with digital thermometer: Description: Stainless steel probe, 21.3 mm diameter, length from 0.5 m to 6 m (to be specified), with handles, beveled tip topped by a Type 94000 digital display in an IP65-rated aluminum housing, dimensions 80 x 82 x 92 mm, push-button power switch. SENSOR: 3-wire Pt100 Class B probe, Display: 3-digit 7-segment LED, 1000-point range, -9.9°C to 99.9°C, Power supply: 9-volt battery

Grease nipple sensors

Downloads:

Grease nipple sensors

Lubrication sensor: allows a lubrication port to be used for temperature measurement without compromising the lubrication function (side lubrication port); the sensor’s effective length can be adjusted using a sliding connector.

Duplex sheath sensors

Downloads:

Duplex sheath sensors

Sensor with dual measurement wells: allows a calibration element to be inserted to verify the process measurement

Level probes

Downloads:

Level probes

• Tank or reservoir temperature measurement • Analog or digital technology Standard sensing elements: PT100, CTN, CTP, PT1000 or addressable digital sensing elements allowing the connection of 24 sensors via 3-wire wiring!! Temperature range: –55°C to +125°C • ATEX certification Notification: 01atex 6052x (Zone 0 or Zone 20) • Outer sheath depending on application hydrocarbon resistance (PTFE or synthetic rubber) Food-grade compatible (PER) Very low adhesion Small diameter: 14 mm to 20 mm IP68 waterproof

Magnetic probes

Downloads:

Magnetic probes

MAGNETIC SENSOR (head-mounted or cable-mounted) type: SPM for surface measurement – Very quick to install. – Sensing element: Pt 100, PT1000, CTN, … – 2-, 3-, or 4-wire configuration – Available in thermocouple types: K, J, T, … – Temperature resistance: 400°C continuous (depending on model)

Stator winding probes

Downloads:

Stator winding probes

Stator winding sensor providing continuous protection for motors or generators. – Sensing element: Pt 100 Ohms at 0°C, conforming to IEC 751 Class B (other accuracy classes available upon request) – 3-wire or 4-wire configuration. – Manufactured in accordance with NF C42-331. – Dielectric strength: 5000 Vac. – Insulation resistance > 500 MΩ. – Temperature resistance: 200°C peak and 180°C continuous. – Housing material: epoxy glass. – Excellent pressure resistance (for vacuum encapsulation). – Special twisted-pair cable output (to limit induced currents). – Other configurations available upon request.

SPAL Food Sensors

Downloads:

SPAI

In food and pharmaceutical applications, no compromises can be made regarding the quality of the equipment used; its fundamental requirement is that it must not compromise the hygiene standards of the system. When it comes to process instrumentation, hygiene involves preventing product buildup and ensuring easy on-site cleaning. Temperature probes must successfully pass the on-site cleanability test. The materials used in the construction of these probes (316L stainless steel and FDA-approved rubber/plastic) and the extremely low surface roughness of the external surfaces (mirror polish) completely eliminate the risk of corrosion and product contamination. Regardless of the type of aseptic process connection used, performance in terms of accuracy, response time, etc., is maximized, even when the probe is only partially immersed in the process liquid.

Air conditioning sensors

Downloads:

Air conditioning sensors

Outdoor ambient temperature measurement, air ducts, and ventilation ducts. – Type MA connection head (other head types available upon request) – Sensing element: NTC, Pt 100, PT1000, etc., Class B (specify other types) – Mounted on an adhesive base – Secured via a 1/2″ G cylindrical fitting welded to the duct (other types available upon request) – 316L stainless steel protective sheath, Ø 6 x 0.5 mm, open-ended. – Effective lengths: 50 – 100 – 150 mm (other lengths available upon request) – Operating temperature: –50 to +200 °C.