Our products

Products

MINIATURE INSTRUMENTATION POWER SUPPLY

Downloads:

al25

• Universal input: 20–265 V AC/DC

• Full protection: short circuits, overloads, thermal protection

• 1 to 3 isolated outputs (1 watt per output)

3.3 V to 24 V up to 72 V via coupling
: 30 mA to 500 mA depending on the output voltage

• Very compact size: 62 x 63 x 23 mm

• 4–20 mA loop power supply applications, instrumentation

The standard version of the AL25 is designed to provide a separate power supply for 4–20 mA current loops.
It is a very compact and fully protected unit, available with 1 to 3 isolated outputs that are current-limited to
protect sensors in the event of a loop fault.
This power supply can be customized for any other single or symmetrical output voltage.

VARIABLE POWER SUPPLY ON DIN RAIL

Downloads:

al200v

300W, adjustable via external or internal setpoint

• Output adjustable via external setpoint, max. 300 Watts
: 0–30 Vdc / 10 A; 0–48 Vdc / 5 A; 0–60 V / 5 A
: ±48 Vdc / 5 A; other configurations available upon request

• Setpoint input: 0–10 V, 4–20 mA, or potentiometer
• AC power supply: 85….265Vac (50Hz, 60Hz)
• Analog output current feedback 4-20mA or 0-10V
• Full protection: Short-circuit, overload, and thermal
• DIN rail or surface-mount installation

-Medium-power industrial power supply with variable output, adjustable via an analog input, which can also serve as a high-output amplifier.

– Hybrid power supply combining switch-mode post-regulation and variable linear regulation, enabling a combination of high efficiency and low noise.

DIN POWER SUPPLY UP TO 3000 WATTS

al200

• DIN rail or surface mounting
AL200HD 3000 Watts or up to 6 x 500W outputs
AL200 2500 Watts or up to 5 x 500W outputs
AL200L 2000 Watts or up to 4 x 500W outputs

• Output voltage: 12 Vdc–240 Vdc
• Input voltage: DC, 50 Hz, 60 Hz
–265 VAC single-phase
–550 VAC two-phase/three-phase

• Protection: short circuits, overloads, and thermal
• Option: Ethernet connection for remote monitoring
Output diode enabling parallel connection
Watchdog relay for output voltage monitoring
Analog output 0..10V, 4..20mA representing the output current
-Industrial power supply, rugged, configurable on request, fully protected, and available
with 1 to 6 isolated or common-ground outputs. Applications: industry, energy, photovoltaics, wind power.

VARIABLE POWER SUPPLY ON DIN RAIL

Downloads:

al175v

Adjustable via an external or internal setpoint

• Output adjustable via external setpoint, max. 200 Watts
: 0–30 Vdc / 5 A; 0–48 Vdc / 2 A; 0–60 V / 1.8 A
: ±48 Vdc / 3 A
: other options available upon request

• Setpoint input
, 0–10 V, 4–20 mA, or potentiometer

• AC or DC power supply
, 48 VAC, 85–265 VAC (50 Hz, 60 Hz, 400 Hz)

• Analog output current signal:
4–20 mA or 0–10 V

• Full protection
: Short circuits, overloads, and thermal protection

• DIN rail or ventilated surface-mount installation
Medium-power industrial power supply with variable output, adjustable via an analog input, which can
also serve as a high-output amplifier.

AC-DC OR DC-DC POWER SUPPLY UP TO 1500 WATTS

Downloads:

al175

• DIN rail or surface-mount installation

Maximum total power: 1500 watts, 1 to 6 outputs
; Output voltage: 5 Vdc to 480 Vdc

• AC input: Switching regulation
85–265 VAC (50 Hz, 60 Hz, 400 Hz)

• Protection: short circuits, overloads, and thermal protection

AL175L 500 Watts max, natural convection
AL175 1000 Watts max, forced-air
AL175HD 1500 Watts max, forced-air
AL175R Redundant version
AL175HV High-voltage input version, 900 to 2200 VAC or DC

• Option: Ethernet connection for remote monitoring (AL175-CMTCP)
Parallel connection diodes (current sharing)
Watchdog relay “OK” output
Analog output 0–10 V; 4–20 mA current signal

HIGH-DENSITY DIN RAIL POWER SUPPLY

Downloads:

al140l

DC or AC input

• AL140L: Single-phase, wide-range DC input
–85 VAC and 110 VDC–320 VDC
• AL140L-HV: High-voltage or three-phase mains input
–85 VAC….528 Vac and 120Vdc….750Vdc
• AL140L-THV: Very high voltage DC or AC input
200Vac….800Vac and 200Vdc….1500Vdc

• Short-circuit, overload, and thermal protection
• 1 to 3 isolated outputs, 10 to 180 watts total
Outputs can be linked

• DIN rail mounting, natural convection cooling
• Applications: Photovoltaics, automation, machinery, instrumentation
Robust, medium-power industrial power supply, fully protected (module encapsulated in resin)
Available with 1 to 3 isolated and fully independent outputs.

MEDIUM POWER SUPPLY 500 WATTS

Downloads:

al125

• DIN rail or surface-mount installation
Total 500 Watts, 1 to 4 isolated outputs or 0V common
Single-voltage output: 3.3Vdc to 400Vdc
Symmetrical voltage output: +/-3.3Vdc to +/-100Vdc

• Universal input: 85–265 VAC (50 Hz, 60 Hz, 400 Hz)
• Full protection against short circuits, overloads, and thermal failure
• AL125-WD Watchdog relay output (changeover contact)

Rugged, medium-power industrial power supply, customizable upon request, fully protected, and available in
s with 1 to 4 isolated outputs or 0V common

DISPLAY AND TECHNICAL FAULT MANAGEMENT CENTER

Downloads:

afl144hv

• 16 digital inputs (127 Vdc or 48 Vdc)
– 1 status feedback output per input
– 3 alarm grouping relay outputs (2RT)
– selection of the grouping channel for each input
– Three-color LED indicating the selected output channel

• Stored and transient alarms
– Stored status LED for each channel
– Transient (pulse) group relay outputs
– Acknowledgment via front panel or digital input
– Lamp test via front panel or digital input

• Passive Technology
to enhance functional safety

• Large format: 144 x 144 mm
• Power supply: 127 Vdc ± 20% or 48 Vdc ± 20%
The AFL144 is an alarm control panel that integrates all the functions necessary for local or remote signaling:
Display logging and acknowledgment, individual and grouped outputs selectable across 3 channels.
Designed for direct panel mounting, the unit can be installed in a rack, on a console, or in a cabinet.

DISPLAY AND TECHNICAL FAULT MANAGEMENT CENTER

Downloads:

afl144

• 16 dry contact digital inputs
– 1 relay output per input (status feedback)
– 3 alarm group relay outputs
– selection of the group channel for each input
– Three-color LED indicating the selected output channel

• Stored and transient alarms
– Stored status LED for each channel
– Dual relay outputs for grouped alarms (stored and transient)
– Acknowledgment via front panel or digital input
– Lamp test via front panel or digital input

• Passive Technology
to enhance functional safety

• Large format: 144 x 144 mm
• Universal power supply: 20–265 V AC/DC
The AFL144 is an alarm control panel that integrates all the functions necessary for local or remote signaling:
Event logging, alarm acknowledgment, and individual and grouped outputs with or without latching.
Designed for direct flush mounting, the unit can be installed in a rack, on a console, or in a cabinet.

DISPLAY AND TECHNICAL FAULT MANAGEMENT CENTER

Downloads:

afl100

• AFL100/8: 8 digital inputs
• AFL100/16: 16 digital inputs
• AFL100L: Display-only version
• AFL100/R option: 1 relay output per digital input
• Communication
AFL100/CP: RS485 Profibus-DP connection
AFL100/CM: RS485 Modbus connection
AFL100/CMTCP: Ethernet Modbus-TCP connection
AFL100/SNMP: Ethernet SNMP connection
• Universal power supply: 20 …. 265 Vac-dc
The AFL100 is a technical fault processing unit designed to replace filament indicators on cabinet fronts
and incorporating all the functions necessary for local or remote signaling: Storage, flashing,
acknowledgment, and alarm. Designed for direct panel mounting, it can be installed in a rack, on a console, or in a cabinet.
The various options offer complete customization, including the number of inputs, relay outputs, and digital connectivity
available via different protocols.