Our products

AC/DC electrical measurement and control

SINGLE-PHASE POWER VARIATOR

Downloads:

vpl74

• Variable full-wave dimmers
Voltage range from 200 VAC to 440 VAC Also available in 24 VAC, 48 VAC, 115 VAC, etc.
• Output power: 7 kW at 230 V – 12 kW at 400 V
Current range from 0.1 A to 30 A Integrated fast-acting fuse
• Internal proportional setpoint Adjustment via potentiometer

• Application: Plastics processing
Ovens, Dryers
Climate chambers,
Test benches.
Heating collar
(not suitable for inductive loads)

A compact, self-contained unit that provides proportional power control of resistive loads
using variable full-wave pulses; can be used with most heating elements.

SINGLE-PHASE POWER VARIATOR

Downloads:

vpl73

• Two modulation modes available
: Full-wave train VPL73-TR
: Phase angle modulation VPL73-PH
• Maximum output power: 6 kW
Current range: 0.2 A to 25 A Built-in fast-acting fuse
• Internal proportional setpoint Adjustment via potentiometer

• Applications:
Plastics processing
Ovens, Dryers
Climate chambers,
Test benches.
Heating collar
(not suitable for inductive loads)
Compact, standalone unit enabling proportional power control of resistive loads
via variable full-wave bursts (high-inertia load) or phase angle modulation (low-inertia load)
, Can be used with most heating resistors.

POWER GRADER

Downloads:

vpl72

• Selectable firing mode: Phase angle modulation or Full-wave modulation
• Wide input voltage range available: 24Vac, 48Vac, 115Vac, 230Vac, 400Vac
• Output power
VPL72 – 115: 5 kW in 115-volt version
VPL72 – 230: 9 kW in the 230-volt version
VPL72 – 400: 16 kW in the 400-volt version
Current range from 0.1 A to 40 A
• Switchable proportional setpoint
– Internal via potentiometer
– External (4–20 mA or 0–10 V)
• Application: plastics processing
Mini ovens, climate chambers, test benches,
Lighting, infrared lamps
heating elements, heating collars, dryers, etc.


Analog-controlled power controller that supports "full-wave" or "
" modulation via phase angle control, enabling extremely precise and rapid modulation of resistive loads, even in systems with low thermal inertia such as infrared systems.

SINGLE-PHASE POWER RATIO CONTROLLER

Downloads:

vpl50

DIN rail mounting for inductive or resistive loads VPL50
• Phase angle modulation
• Maximum output power: 600 Watts
Current range from 0.1A to 2.5A Built-in fast-acting fuse
• Internal proportional setpoint Adjustment via multi-turn trimmer
• Application:
Speed control for fans
Pump flow adjustment
Motor control
Dimmer for infrared lamps, lighting, etc.



The VPL50 is a compact, self-contained unit that provides proportional power control for inductive or resistive loads via phase-angle modulation. It is suitable for both lighting and speed control of small single-phase motors.

GRADATOR, POWER VARIATOR

Downloads:

vpl125

• Full-wave power modulation, 2-second cycle
• Single-phase and three-phase models: 230 VAC, 400 VAC
• Output power
VPL125-1PH: 3 kW, single-phase 230 V
VPL125-3PH: 4 kW, three-phase 400 V

• Setpoint via pushbutton
– Power 0–100%, Increment 0.5%
– Setpoint memory
• Applications:
– plastics processing
– Pastries, climate chambers, test benches,
– heating elements, heating collars, dryers, etc.

An incrementally controlled power regulator that enables "full-wave"
for resistive loads, designed for power control applications involving heating resistors.

PHASEMETER FOR ALTERNATING VOLTAGES

Downloads:

phl165

• Phase shift measurement: -180° to +180°; configurable phase shift offset and sign; frequency range from 40 to 70 Hz
• Two isolated voltage inputs with dual ratings: 150 VAC and 400 VAC
• Up to 3 analog outputs
• Option: 2 relay outputs
• Modbus TCP Ethernet connection option Embedded web server
• 2-line, 16-character LCD display

The PHL165 measures the phase shift between two signals of the same frequency; its isolated inputs
and internal filters provide strong common-mode rejection, enabling reliable
measurement in an industrial environment.

VOLTMETER, AMPEREMETER, TRMS FREQUENCY METER

Downloads:

ipl36l

AC 50Hz, 60Hz, 400Hz and DC
• AC + DC RMS measurements: single-phase or balanced three-phase 0…440Hz PWM, Waveform Phase angle variation
Signals with high harmonic content
• Multi-sensor current input:
shunt, transformer, Rogowski coil, Hall effect or direct sensor 1A and 5A
• Programmable: functions: voltmeter, ammeter, frequency meter
• 6-digit measurement display, 4-digit alphanumeric unit display
Display: U, I, Hz
• Options: isolated analog output, 2 relay outputs
RS485 Modbus RTU
Ethernet Modbus TCP (6 simultaneous connections) and SNMP
• Wide-range universal AC/DC power supply

The IPL36L is a transducer indicator designed to measure, monitor, and transmit voltage
, current, and, if required, the frequency of an AC or DC electrical circuit. It can be quickly set up by simply programming the inputs
. The various output options enable a wide range of applications:
measurement, protection, control, and more.

Measurement:
– continuous or alternating, single-phase or balanced three-phase

WATT METER AND TRMS (TRUE RMS) ENERGY METER

Downloads:

ipl36

AC 50Hz, 60Hz, 400Hz, and DC
• AC + DC RMS measurements: single-phase or balanced three-phase 0…440Hz PWM, waveform, phase angle variation
Signals with high harmonic content
• Multi-sensor current input:
shunt, transformer, Rogowski coil,
Hall effect or direct sensor 1A and 5A
• Programmable:
voltmeter, ammeter, wattmeter, varmeter
power factor, Cos-phi, frequency meter
• 6-digit measurement display, format: 96 x 48 mm
selected measurement type on 4-digit alphanumeric display
Display: U, I, Cos, P, Q, S, Hz (energy optional)
• Options: isolated analog output, 2 relay outputs RS485 Modbus
ETHERNET Modbus TCP (6 simultaneous connections) and SNMP
• Wide-range universal AC/DC power supply

The IPL36 is a display unit designed for measuring, monitoring, and transmitting electrical parameters.
Setup is quick and easy through simple programming of transformer ratios or shunt sensitivity.
The various output options enable a wide range of applications: measurement, protection, control, and more.
Measurement:
– DC or AC power systems, single-phase or balanced three-phase

MEASUREMENT CENTER, ELECTRICAL NETWORK ANALYZER

Downloads:

ipl144v

• Power supply: continuous, alternating, single-phase, three-phase, balanced, unbalanced, with neutral, without neutral,
• Display: 3 values on 3 digits, 1 value on 4 digits, available in Red, Green, Yellow, Blue

• IPL144V/R: 2 relays for alarm or counting,
• IPL144V/CM: RS485 MODBUS/JBUS interface.
• IPL144V/CP: RS485 PROFIBUS DP interface
• IPL144V/CMTCP: Ethernet Modbus TCP interface

The IPL144V is a low-cost, universal power network analyzer. The device comes standard with
measurement, analysis, and data reporting functions that enable it to effectively meet the needs of
the majority of applications.
Applications:
– Measurement, monitoring, control, regulation, and protection.

THREE-STAGE POWER DISSIPATOR

Downloads:

dlb105

• Multi-stage load shedding
• Real-time clock: Off-peak and peak hour management, daylight saving time and standard time switching
• Display: 2-line, 16-character LCD, displays all electrical parameters
• Fully configurable Power limit, load shedding time, load restoration time, load restoration threshold
The DLB105 is a multi-stage load shedding device that limits electrical consumption and transmits,
either the available power to a control system (DLB105/BIN),
or automatically sheds up to three non-priority loads (DLB105/R).
The product can be used independently on a single-phase or three-phase network.
Description:
– Measurement of total active power and comparison to available power
– Measurement of current per phase and limitation to the circuit breaker rating
– Generation of a 3-bit binary output code (8 levels) representing available power (DLB105/BIN)
– Direct control of non-priority loads based on available power (DLB105/R)
– Real-time clock with calendar and automatic daylight saving time adjustment for managing available power.
– Two consumption limits (maximum and economical) can be configured by time slot for each day of the week.