Our products

Products

SINGLE-RAMP LED BAR GRAPH AND 4-DIGIT DISPLAY

bgl136 nav2

Downloads:

bgl136-nav2

Naval-Approved – Group

• Analog input
, 0–4–20 mA, 0–10–20 V (configurable)

• Display:
40-LED strip, 10,000-point red display, brightness adjustment via settings

Basic single-channel version with a 4-digit display and 2 alarm relays

• DIN-rail mountable, 144 x 36 mm, depth 90 mm
IP55 front panel (version without pushbutton)
IP22 rear panel and protective cover
– The BGL136-NAV2 is a digital bar graph that uses a measurement scale to indicate the order of magnitude
of the measurement as well as its variation; its digital display allows for precise reading when necessary.

SINGLE-RAMP LED BAR GRAPH WITH 4-DIGIT DISPLAY

bgl136 nav1

Downloads:

bgl136-nav1

Naval-Approved – Group

• Analog input
, 0–4–20 mA, 0–10–20 V (configurable)

• Display:
40-LED strip, 10,000-point green display
option to set multiple colors in a strip

• BGL136-NAV1
Single-ramp version with 4-digit display, without relay

• BGL136-NAV1/R
Single-ramp version with 4-digit display and relay

• DIN-sized flush-mount unit
, 144 x 36 mm


The BGL136-NAV1 is a digital bar graph that uses a measurement ramp to provide an indication of the order of magnitude of the measurement and its variation; its digital display allows for precise readings when necessary.

SINGLE CIRCULAR BAR GRAPH LED STRIP

Downloads:

bgcl96

96 x 96 mm
• All process and temperature inputs
V, mV, mA, sensor power supply, potentiometer, frequency, strain gauge, thermocouple, PT100)
(programming via front panel or USB)

• Circular LED strip with 55 LEDs (choice of colors)
• 10,000-point measurement display
• Up to 4 relay outputs
• Option: isolated analog output
RS485 Modbus/Profibus interface
Ethernet Modbus TCP interface

• Plug-in connectors
• Universal power supply
• Applications: temperature measurement, weighing, frequency measurement, process measurement
, signal conditioning, threshold relays, control
– The BGCL96 is a compact, universal digital bar graph display for analog, process, and temperature inputs,
configurable via plain-language interface (no manual required) and featuring dual measurement display (ramp and display)

PORTABLE OR BUILT-IN ANALOG SIGNAL ACQUISITION UNIT

aqv144

Downloads:

aqv144

PoE Ethernet connection

Measurement inputs: (all measurement inputs are isolated)
6 K-type thermocouple inputs
6 4-wire PT100 inputs
6 0…10 Vdc inputs
6 4…20mA (with or without sensor power supply)
6 pulse inputs 0..100 Hz (dry contact or 5V to 24V voltage)
Front panel:
– 4-digit measurement display with 14.2 mm LEDs
– indication of the selected channel on an auxiliary alphanumeric display
– LED for scrolling or static display mode,
– Three-button keypad for full configuration
of the device (IP address and clock)
Communication:
– Ethernet: Modbus-TCP protocol
PoE power supply via the Ethernet connection

MODBUS ETHERNET DISPLAY INDICATOR

Downloads:

anl48

TCP or RS-485, Modbus RTU

• Measurement data transmission via digital connection
– Ethernet Modbus TCP (client/master or server/slave mode)
– RS485 Modbus/Profibus (slave mode)

• 5-digit display
• Watchdog
– relay output on loss of communication


• Option: 2 alarm relay outputs
• Option: isolated analog output
The ANL48 is a digital display designed to show measurements available over an Ethernet or RS485 network. It can operate in client mode (automatic polling of a variable from a sensor),
or in server mode (a PLC writes the value to be displayed to the display).

6-DIGIT DISPLAY INDICATOR BCD INPUT, GRAY BINARY

Downloads:

anl36

• 16 parallel digital inputs (dry contact or voltage)
BCD, GRAY, or binary code
• Display
6-digit display, 96 x 48 mm format
4-digit alphanumeric unit
• Options:
isolated 4-20 mA analog output
relay output
RS485 Modbus connection
Ethernet Modbus TCP connection
• Application: Interface for encoders with parallel outputs

The ANL36 is a display with parallel digital inputs; it also allows the input code
to be transmitted via a communication port (RS485 or Ethernet) or converted into an analog signal.
The product’s configuration (resolution, encoding type: BCD, GRAY, BINARY, etc.) makes it suitable for the
vast majority of applications.

6-DIGIT BCD DISPLAY WITH MULTIPLEXED INPUTS

Downloads:

anl24

• Digital control inputs
BCD inputs for displayed value
BCD inputs for digit selection
Display test input
• Display
6-digit 7-segment LED display, 8 mm high
Analog input for brightness adjustment
96 x 24 mm display
IP54-rated front panel
• Application
Display interface for PLC
TheANL24 is a BCD (Binary-Coded Decimal) digital display that converts binary data into a readable format
using 7-segment displays. It can be used to display information such as:
time, temperatures, measurements, or codes. To reduce the number of wires, it features BCD inputs
shared by all digits and digit selection inputs, allowing the value to be displayed
sequentially, digit by digit, using a programmable logic controller (PLC), for example.

ETHERNET DIGITAL FIELD DISPLAY

Downloads:

anl201

IP66 outdoor version for mounting on a support tube or wall

• ANL201ADF: ATEX explosion-proof option

• Display controlled via Ethernet, Wi-Fi, or RS485
• 24 VDC auxiliary power supply

• 5-digit LED display (red or green)


The ANL201 is a digital field display that shows variables from a communication bus. This product, which is extremely easy to install, is designed for use
in harsh outdoor environments or explosive atmospheres and offers a wide range of mounting options.

24 VDC Instrumentation Power Supply for 4–20 mA Loop in a 19″ Rack

alr20

Downloads:

alr20 al100

• Linear or pulse-width modulation (PWM) version
• Full protection: short circuits, overloads, thermal

• 1 to 8 isolated outputs AL100
• 1 to 4 isolated outputs ALR20
• Compact design

• Applications
, 4–20 mA loop power supply
, instrumentation, sensors, etc.

These power supplies are available with 1 to 8 outputs and are particularly well-suited for use with converters in a two-wire technical
(powered by the 4–20 mA loop). The isolation between each output eliminates ground-loop
s that could affect the measurement. Since each output is independent and low-power, any risk of equipment damage is eliminated compared to using a single-output high-power supply. The independence of each loop significantly increases the reliability of the installation. The outputs allow for all wiring combinations to adapt to specific needs; connecting them in series or parallel enables the creation of a balanced output, increasing the output current or voltage.

MEDIUM POWER RACK POWER SUPPLY

alpk

Downloads:

alpk

75 Watts total across up to 3 outputs
• Universal input: 85–265 VAC/DC, switching regulation
• Comprehensive protection
short circuits
overloads
thermal
• Fully isolated
between each output
Robust, fully protected, rack-mountable industrial power supply with medium power output, available with 1 to 3 isolated outputs.

Showing Slide 1 of 11