Our products

Conditioners and isolators

ANALOG-TO-PULSE-WAVEFORM CONVERTER FOR SOLID-STATE RELAY CONTROL

cmi30

Downloads:

cmi30

• Direct control of synchronous solid-state relays using full-wave drive (MLi, PWM)
– Fixed-rate mode
– Analog setpoint converter mode
• Switchable proportional setpoint
– Internal via potentiometer
– External (4–20 mA, 0–10 V, potentiometer)
• Application:
– Control of heating resistors for:
– furnaces, oil baths, industrial processes
– climatic chambers,
– test benches, etc.
• Voltage output or dry contact via solid-state relay: 0…10V
Analog-controlled (internal or external) power controller with variable duty cycle output
enabling control of a “zero-crossing” type solid-state relay for heating element regulation.

GRAY CODE COMPARATOR FOR PARALLEL OUTPUT ENCODERS

Downloads:

ccn165

• 2 groups of 25 parallel digital inputs (4 to 25 bits in Gray code)

• 3 relay outputs + 1 watchdog output with programmable differential input thresholds

• Application: Synchronization control of two sensors


The CCN165 is a parallel digital comparator that enables simultaneous monitoring of two mechanical components. The relay outputs trigger a shutdown in the event of an excessive deviation or a failure in the operating
. The display allows for quick operational diagnostics and product configuration.

4–20 mA ANALOG-TO-DIGITAL CONVERTER TO BCD – GRAY – BINARY

Downloads:

can105

• Analog Input
, 4–20 mA, 12-bit resolution

• Parallel digital outputs
, GRAY code, binary, or BCD
(14 bits + enable)

• Modbus TCP Ethernet Communication

The CAN105 is an analog-to-digital converter that converts an analog input signal (4–20 mA) into a binary, Gray, or parallel BCD (
) format; the display allows for quick diagnosis of proper operation (displaying the input current, the corresponding physical range, and the status of the outputs).

ISOLATED ANALOG TRANSMITTER POWERED BY THE 4..20MA LOOP

Downloads:

cal45

• CALP45: Pt100, Pt1000, Ptxxx input, 2- or 3-wire configuration
• CALT45: Thermocouple input
• CAL45: mV, V (dc), mA (dc), potentiometer input
• Isolation: input/output
• 2-wire technique powered by the 4-20mA loop

• LED for immediate monitoring of the loop and sensor
Green LED: 4–20 mA loop OK; Red LED: sensor fault

• SIL 2 and SIL 3 compliance in accordance with IEC 61508

The CAL45 series signal conditioners convert input signals from Pt100, thermocouples, mA, mV
, or potentiometers into a 4–20 mA current output using isolated 2-wire technology. Their use is recommended
to eliminate ground loops or to protect the data acquisition system.

ANALOG TRANSMITTER FOR PROBE HEAD MOUNTING

Downloads:

cal40

PT100, PT1000, or Potentiometer Input

• CALP40 Pt100–Pt1000 temperature transmitter
• CALpot40 Potentiometer input
• CALP40Si ATEX-certified intrinsically safe version
• Spring-loaded anti-vibration probe head mounting

• 2-wire technology powered by the 4–20 mA loop
• LEDs for immediate monitoring of the loop and sensor
Green LED: 4–20 mA loop OK
Red LED: sensor fault


• SIL2 and SIL3 compliance according to IEC 61508
The CAL40 measurement converter converts signals from temperature probes or position sensors (potentiometers) into a 4….20 mA 2-wire signal (powered by the measurement loop)
DESCRIPTION:
Input Temperature measurement:
– Pt100 or Pt1000 platinum resistance probes, 3-wire configuration
– Linearization and cable length compensation
– Customization of the measurement range at the end of manufacturing

4-CHANNEL 4–20 mA LOOP ISOLATOR

cal4-100ig

CAL4/100ig CAL4/100igM
• CAL4/100ig (loop duplicator)

• CAL4/100ig4: 1 or 2 inputs to 4 outputs

• CAL4/100igM (multi-loop isolator)

• CAL4/100igM4: 4 inputs, 4 outputs

• Inputs: 0–10 V; 4–20 mA (active or passive)
• Outputs: 0–10 V; 4–20 mA
with test terminals and loop status LEDs

• Universal AC/DC power supply 20–265 V

• Hart transparency option
• SIL2 and SIL3 options according to IEC 61508
A series of galvanic isolators consisting of several independent and self-contained cells designed for processing 0–4–20 mA current loops. Each input can be active or passive, allowing for the measurement of current from an active transmitter or the powering of a 2-wire converter and measurement of the loop current.
Due to the modular design of these isolators, it is possible to isolate up to 4 independent loops or
to obtain, by connecting the inputs in series, up to 4 isolated copies of the same loop.
Similarly, connecting the outputs in series or parallel allows for higher loads or
higher output currents.

UNIVERSAL ANALOG SIGNAL ISOLATOR CONDITIONER

cal30

Downloads:

cal30-35

• All types of inputs via interchangeable measurement cards
-V, mV, mA, potentiometer, frequency, thermocouple, PT100, PT1000, strain gauge

• Single-ended or differential analog output:
0..4..20mA; 0…1…5…10V; +/-20mA; +/-10V; frequency
• Special function:
Maximum value selector for 2 analog inputs
Minimum value selector for 2 analog inputs
Voltage-to-frequency converter,….
Summator, differentiator, absolute value, etc.
• Triple galvanic isolation
Input / output / power supply
• High-speed signal version
minimum response time < 50us
bandwidth up to 20 kHz
The CAL30 and CAL35 measurement converters allow for the transformation, adaptation, and isolation of a very
wide variety of analog signals. A modular internal design (interchangeable input card)
allows for the creation of new functionalities tailored to each specific need.

SELF-POWERED ISOLATOR FOR A CURRENT LOOP

cal25igd

Downloads:

cal25igd

• Up to 8 isolated channels
Available with 1 to 8 independent channels

• Very high density, 8 insulators, 23 mm wide

• No auxiliary power supply; self-powered by loop current

• Excellente linéarité : 0.1%
• Faible temps de réponse : < 2 ms
• Faible perte d’insertion : < 65 ohms
• Connectique débrochable
• Option SIL2 et SIL3 selon IEC 61508
• Applications
Isolation entres automates
Le séparateur galvanique CAL25IGD est dédié à l’isolation de boucle de courant 0…4…20mA. Sans alimentation
auxiliaire, il s’insère facilement dans les boucles de courants existante, pour éliminer les courants de fuite liés
au rebouclage de masse, ou les problèmes de mode commun. Sa forte intégration permet un important gain de
place. La technologie de l’isolateur assure excellente fiabilité et une durée de vie supérieure à 40 ans.

SELF-POWERED GALVANIC ISOLATOR FOR CURRENT LOOP

cal25ig

Downloads:

cal25ig

0–10 mA, 0–20 mA, 4–20 mA, 10–50 mA, …

1 to 2 independent channels with Hart transparency option
3 independent channels with 2500 V rms electrical withstand voltage
1 channel, transmitter isolation using 2-wire technology

• No auxiliary power supply; self-powered by loop current

• Excellent linearity: 0.1%
• Fast response time: < 2 ms
• Very low insertion loss: < 65 ohms
• Wide range, 1:1 ratio: 0..4…10…20…50mA
• SIL2 and SIL3 options according to IEC 61508

CAL25IG-type galvanic isolators are designed for isolating 0–4–20 mA current loops.
Since they do not require an auxiliary power supply, they can be easily integrated into existing current loops
to eliminate ground loops or common-mode issues.

ANALOG TRANSMITTER FOR PT100, THERMOCOUPLE

cal25

• CALP25 PT100, PT1000 input (2- or 3-wire configuration)
• CALT25 thermocouple input
• CAL25 mV, mA, and potentiometer inputs
• 2-wire configuration, loop-powered by the 4-20 mA loop
• 3-wire configuration, 0-10 V output
• CAL25isoV isolator
0..10 V inputs, 0…10 V output, 24 Vdc power supply
+/-10 V inputs, +/-10 V output, 24 Vdc power supply

• Loop and sensor status LEDs
Green LED: 4–20 mA loop OK
Red LED: Sensor fault

• SIL2 and SIL3 compliance according to IEC 61508
The CAL25 series signal conditioners allow for a Pt100, thermocouple, mA, mV, or
potentiometer input to produce a 4…20 mA current output (2-wire configuration) or a
0..1..5..10 V voltage output (3-wire configuration). The CAL25isoV is a compact 1:1 voltage isolator