Our products

Conditioners and isolators

ISOLATED HART TEMPERATURE TRANSMITTER WITH PT100 AND THERMOCOUPLE INPUT

cnl40ig

• Universal PT100 input (3- or 4-wire), thermocouples, mA, mV
, galvanic isolation + HART protocol
• Fully configurable RS232 and HART
• FDT-certified HART DTM drivers
• 2-wire technology powered by the 4-20 mA loop
• SIL2 compliance according to IEC 61508

The CNL40ig is a programmable transmitter for pyrometric probe heads, enabling
all temperature measurements (PT100 and thermocouples) across all measurement ranges to be covered with
a single product. The CNL40igH incorporates the HART communication protocol, which is FDT-certified and available in
SIL2 compliance according to the IEC 61508 standard.

PROGRAMMABLE TRANSMITTER FOR MOUNTING ON THE PROBE HEAD

Downloads:

cnl40

• CNL40 with PT100 and thermocouple inputs
• CNL40D Dual-channel version with 2 independent transmitters in a single housing
• Fully configurable USB connection
• 2-wire configuration powered by the 4–20 mA loop, without isolation

The CNL40 is a programmable temperature transmitter designed for mounting on the tip of a pyrometric probe.
It supports all industrial temperature sensors (PT100 and thermocouples) across all
measurement ranges with a single product

CONVERTER FOR SSI ENCODER ANALOG OUTPUT 0..4..20MA

cnl35ssi

Downloads:

cnl35ssi

• Input: Synchronous Serial Interface (SSI) Master or slave mode
SSI formats: 8 to 32 bits, binary or Gray code Encoder power supply: 24 V

• Display
4-digit display, plain-language configuration
• Options: 2 relay outputs, 2 isolated analog outputs
• Plug-in connectors
• Universal AC and DC power supply
The CNL35SSi is a digital-to-analog converter for SSi encoders featuring 2 analog outputs
and 2 relay outputs
DESCRIPTION:
The SSi interface consists of 2 pairs of wires:
one pair for transmitting the master’s clock signals
and the other pair for transmitting data from the slave (encoder).
the number of clock pulses depends on the number of data bits
to be transmitted.
A third pair of wires optionally provides power to the encoder.

PROGRAMMABLE ANALOG SIGNAL CONDITIONER

Downloads:

cnl35l

• Very wide range of analog process and temperature inputs
, voltage, current, sensor power supply, potentiometer, resistance, frequency, duty cycle,
, strain gauge, thermocouple, 3-wire and 4-wire PT100, PT1000, Ni100, Ni1000

• 1 or 2 isolated analog outputs
(Version without "threshold detector" analog output: DNL35L)

• Up to 4 relay outputs
• Fast response time of up to 35 ms
• Measurement display (10,000 points)
(programming via front panel or USB-RS232 cable)

• Plug-in connectors
• Universal power supply 20….265Vac-dc
• SIL2 option according to IEC 61508
The CNL35L is the programmable signal conditioner with the widest range of inputs and calculation functions
on the market, capable of being equipped with 2 isolated analog outputs, 4 alarm relays, and a 4-digit display.

HIGH-VOLTAGE ISOLATION AMPLIFIER, SIGNAL CONDITIONER

Downloads:

cnl34dhig

• Temperature, voltage, and current inputs: PT100, thermocouple, Volts (up to 5000 Vdc), mV (shunt), mA…
• Very high galvanic isolation with a dielectric strength of 10 kV AC / 15 kV DC (continuous)
• Fully configurable via serial connection
• Universal AC/DC power supply

The CNL34DHig is a transmitter designed for measurement applications on equipment that may be exposed to high voltages (power distribution, railways, transformers, motors, alternators, etc.) and requires maximum safety.

PT100 AND THERMOCOUPLE TRANSMITTER, HART, INSULATED

cnl25igd

Downloads:

cnl25igd

• Temperature and process inputs
, PT100 platinum sensor (2-, 3-, or 4-wire configuration), thermocouple,
, mV, mA, potentiometer

• 2-wire output: powered by the 4–20 mA loop
• Galvanic isolation: input/output
• Fully configurable: USB connection, HART protocol, FDT-certified HART DTM drivers

• SIL2 compliance according to IEC 61508
• Compact width: 18 mm
The CNL25igD is an isolated transmitter for DIN rail mounting, powered by the 4–20 mA loop
, designed for measuring temperature or process signals. The CNL25igDH incorporates the HART communication protocol
, is FDT-certified, and is available in SIL2 compliance according to IEC 61508.

MINIATURE ISOLATED PROGRAMMABLE TEMPERATURE TRANSMITTER

cnl25ig

Downloads:

cnl25ig

• Process and temperature inputs
: voltage (V, mV), current (mA), potentiometer (
), thermocouple, PT100
• 2-wire technique powered by the 4-20mA loop
• Galvanic isolation
• Fully configurable
• Compact DIN rail housing
The CNL25ig is a programmable, isolated DIN rail-mounted transmitter, powered by the 4…20mA loop
and featuring a very compact design for applications with limited space.

PROGRAMMABLE TEMPERATURE TRANSMITTER PT100, THERMOCOUPLE

Downloads:

cnl25d

• Temperature input: PT100, thermocouple
• Compact design: 17 mm
• Plug-in connectors
• 2-wire technology: powered by the 4-20 mA loop
• Fully configurable: USB connection

The CNL25 is an entry-level, DIN-rail-mountable, 4–20 mA loop-powered programmable transmitter
that supports all temperature measurement methods (PT100 and thermocouples)
across all measurement ranges with a single product.

GRAY-BCD BINARY CONVERTER WITH 4–20 mA OR 0–10 V OUTPUT FOR ENCODERS WITH PARALLEL OUTPUTS

Downloads:

cna105

• 18 parallel digital inputs (16 bits + sign + enable)
Input in BCD, Gray, or binary code

• Analog Output
: 0–4–20 mA, 0–10 V (16-bit resolution)

• CNA105/R Relay Output Option: 2 programmable thresholds

• Application:
Interface for encoders with parallel outputs
The CNA105 is a digital-to-analog converter that converts the position
of an input encoder into an analog signal; the display allows for quick diagnosis of proper operation.
The product configuration (encoder resolution, encoding type: BCD, GRAY, BINARY, polarity, etc.)
allows it to meet the needs of most applications.
The relay outputs enable local limit switch or alarm control.

PULSE-WIDTH MODULATION POWER SUPPLY FOR SOLID-STATE RELAY CONTROL

cmi70

Downloads:

cmi70

• Direct control of synchronous solid-state relays using full-wave drive
• Switchable proportional setpoint input: 4–20 mA, 0–10 V, 0–20 V, potentiometer
• Application:
Control of heating resistors for:
– ovens, oil baths, industrial processes
– climate chambers,
– test benches…..


The CMi70 converter uses a standard analog signal (4–20 mA; 0–10 V; etc.) to generate a logic signal with a duty cycle ranging from 0 to 100% for controlling power units or solid-state relays
used in heating element control.