Our products

Products

UNIVERSAL PROGRAMMABLE CONVERTER

Downloads:

cnl35

• CNL35: universal input, over 10 types of inputs (temperature and process)
• CNL35/F: fixed-frequency input
• CNL35/R: relay option
• CNL35/S2: second output option
• CNL35/T: reduced response time
• CNL35/SP: 16-bit output

• Fully configurable
• Fully isolated
The CNL35 is a fully configurable, general-purpose digital transmitter for temperature and process inputs

ISOLATION AMPLIFIER, SIGNAL CONDITIONER

Downloads:

cnl34dhig

• Temperature, voltage, and current inputs: PT100, thermocouple, Volts (up to 5000 Vdc), mV (shunt), mA…
• Very high galvanic isolation with a dielectric strength of 10 kV AC / 15 kV DC (continuous)
• Fully configurable via serial connection
• Universal AC/DC power supply

The CNL34DHig is a transmitter designed for measurement applications on equipment that may be exposed to high voltages (power distribution, railways, transformers, motors, alternators, etc.) and requires maximum safety.

PT100 AND THERMOCOUPLE TRANSMITTER

cnl25igd

Downloads:

cnl25igd

• Temperature and process inputs
, PT100 platinum sensor (2-, 3-, or 4-wire configuration), thermocouple,
, mV, mA, potentiometer

• 2-wire output: powered by the 4–20 mA loop
• Galvanic isolation: input/output
• Fully configurable: USB connection, HART protocol, FDT-certified HART DTM drivers

• SIL2 compliance according to IEC 61508
• Compact width: 18 mm
The CNL25igD is an isolated transmitter for DIN rail mounting, powered by the 4–20 mA loop
, designed for measuring temperature or process signals. The CNL25igDH incorporates the HART communication protocol
, is FDT-certified, and is available in SIL2 compliance according to IEC 61508.

MINIATURE ISOLATED PROGRAMMABLE TEMPERATURE TRANSMITTER

cnl25ig

Downloads:

cnl25ig

• Process and temperature inputs
: voltage (V, mV), current (mA), potentiometer (
), thermocouple, PT100
• 2-wire technique powered by the 4-20mA loop
• Galvanic isolation
• Fully configurable
• Compact DIN rail housing
The CNL25ig is a programmable, isolated DIN rail-mounted transmitter, powered by the 4…20mA loop
and featuring a very compact design for applications with limited space.

PROGRAMMABLE TEMPERATURE TRANSMITTER PT100, THERMOCOUPLE

Downloads:

cnl25d

• Temperature input: PT100, thermocouple
• Compact design: 17 mm
• Plug-in connectors
• 2-wire technology: powered by the 4-20 mA loop
• Fully configurable: USB connection

The CNL25 is an entry-level, DIN-rail-mountable, 4–20 mA loop-powered programmable transmitter
that supports all temperature measurement methods (PT100 and thermocouples)
across all measurement ranges with a single product.

PROGRAMMABLE PROCESS CONVERTER

cnl23

Downloads:

cnl23l

• Process inputs (Volt, mA, sensor power supply, potentiometer)
• 2 isolated analog outputs
• CNL23L-H:

HART transparency option

• Fully configurable
• Simulation mode (RS-232) loop calibration

• Low response time: 55 ms
• Universal power supply: 20–265 V AC/DC
The CNL 23L is a process input transmitter featuring two isolated analog outputs
that can be configured independently (loop isolator, signal duplicator, load boost, etc.)

PROGRAMMABLE PROCESS CONVERTER

cnl23

Downloads:

cnl23

• Process inputs: Volts, mA, potentiometer

• Bipolar inputs and outputs (+/-)
• Fully configurable (RS-232)
• 2 analog outputs as standard
• Fast response time: 55 ms

The CNL 23 is a digital-to-analog converter for process inputs. Its quick reconfiguration without the need for adjustment makes it a cost-effective replacement for an analog converter.

ATEX PROGRAMMABLE DIGITAL CONVERTER

cnl20si

Downloads:

cnl20si

• All process and temperature inputs: Volts, mV, mA, analog sensor, potentiometer; thermocouple, PT100

• CNLB20SI: DIN rail mounting
• CNLR20SI: 19″ rack mounting »

• Fully configurable
• Fully isolated 2500V

• RS485 Modbus connection

The CNL20SI is a programmable converter designed for use with sensors in Ex-
s. A single model covers all measurement needs in explosive environments.

CONVERTER FOR A PARALLEL-OUTPUT ENCODER

Downloads:

cna105

• 18 parallel digital inputs (16 bits + sign + enable)
Input in BCD, Gray, or binary code

• Analog Output
: 0–4–20 mA, 0–10 V (16-bit resolution)

• CNA105/R Relay Output Option: 2 programmable thresholds

• Application:
Interface for encoders with parallel outputs
The CNA105 is a digital-to-analog converter that converts the position
of an input encoder into an analog signal; the display allows for quick diagnosis of proper operation.
The product configuration (encoder resolution, encoding type: BCD, GRAY, BINARY, polarity, etc.)
allows it to meet the needs of most applications.
The relay outputs enable local limit switch or alarm control.

4-CHANNEL MEASURING UNIT WITH ISOLATED INPUTS REMOTE ANALOG ACQUISITION

Downloads:

cml70

• 4 isolated analog inputs
– individual configuration for each input.
– 1 alarm threshold per input.
CML70t: thermocouples, 2-wire and 3-wire Pt100, mV, resistance.
CML70pt4: thermocouples, 4-wire Pt100
CML70p: 0…20 mA; 4…20 mA and 0..1..5..10 V (process)
CML70B: 0…24 V, 48 V…127 V…150 V DC (battery monitoring, power supply)

• Communication:
Modbus RTU
Modbus-TCP (Ethernet) 6 simultaneous connections
Embedded web server
SNMP
• Application:
Temperature monitoring: motor, transformer
Voltage monitoring: battery, power supply,
Monitoring relays: temperature, voltage, current.

The CML70 is a compact four-channel data acquisition unit designed for applications requiring high precision and functional safety
; the unit’s full isolation ensures that each measurement is completely independent.