DC input from 1 A to 100 A (or ±1 A to ±100 A)
; bandwidth up to 50 kHz
Hall-effect technology with 25 mm² screw terminal input (5 A to 100 A max.)
Single- or dual-pole current or voltage output: 0–4–20 mA, ±20 mA, ±10 V,
, isolated from the power supply
Direct shunt replacement possible Isolated mV output (no heat dissipation)
Power supply
: 4.5–18 Vdc, 18–36 Vdc, 9–36 Vdc, 18–75 Vdc,
The CAL35CC transmitter measures DC current up to 100 amps, serving as an effective replacement for measuring shunts by reducing insertion losses and providing a conditioned signal (4–20 mA, 0–10 V, or mV). The open-frame version is particularly suitable for retrofitting existing installations and even allows for installation without shutting down the system.
Applications: solar farms, wind farms, batteries, industry
– detection of defective panels
– measurement of power output from each panel
– control of panel orientation
– battery monitoring, DC motor monitoring
– welding