Our products

AC/DC electrical measurement and control

RUGGED ALTERNATING AND CONTINUOUS TRMS CONVERTER WATT METER, VOLT METER, AMPER METER, etc.

Downloads:

cpl36

• RMS AC + DC measurements, ruggedized version
single-phase or balanced three-phase 0…440 Hz with or without neutral
MLI – PWM, Pulse Train, Phase Angle Variation, Signals with high harmonic content
• Multi-sensor current input: shunt, Rogowski coil, Hall effect sensor
• Programmable: Voltmeter, ammeter, wattmeter, varimeter, power factor, Cos phi, frequency meter
• 4-digit measurement display for U, I, Cos, P, Q, Hz
• 2 isolated analog outputs and 2 relay outputs
• Wide-range universal AC/DC power supply

The CPL36 is a ruggedized converter designed for the measurement, monitoring, and transmission of electrical parameters
. It can be quickly configured by simply programming the transformer ratios
or shunt sensitivity. The various output options make it suitable for a wide range of applications.

CURRENT AND VOLTAGE TRANSMITTER

Downloads:

cpl35l

For AC and DC signals
• AC + DC RMS measurements: DC to 440 Hz
PWM, phase angle modulation, wave trains, signals with high harmonic content
• Multi-sensor current input:
shunt, transformer, Rogowski coil, Hall effect sensor or direct input 1A and 5A
• Programmable: voltmeter, ammeter, frequency meter
• 4-digit measurement display for U, I, Hz
• 2 isolated analog outputs for simultaneous voltage and current transducers
• 3 relay outputs
• Ethernet connection with Modbus-TCP and SNMP
• Wide-range universal AC/DC power supply

The CPL35L is a programmable voltage and current measurement converter. Its various output options—
—enable a wide range of applications, including measurement, protection, and control. The second analog output allows
to simultaneously measure voltage and current in a fully isolated manner.

MEASUREMENT CONVERTER, WATTMETER

Downloads:

cpl35

Wattmeter, Voltmeter, Ammeter,….
• AC + DC RMS measurements: 0–440 Hz Single-phase, Two-phase, Balanced three-phase with or without neutral
PWM PWM, Waveform, Phase Angle Variation Signals with high harmonic content
• Multi-sensor current input: shunt, transformer, Rogowski coil Hall effect sensor or direct input 1A and 5A
• Programmable:
Voltmeter, ammeter, wattmeter, varmeter,
power factor, Cos phi, frequency meter
AC and DC energy meter
• 4-digit measurement display: U, I, Cos, P, Q, Hz
• Outputs: 2 analog outputs, 3 relay outputs,
Ethernet connection Modbus-TCP and SNMP
• Wide-range universal AC/DC power supply

The CPL35 is a converter designed for measuring, monitoring, and transmitting electrical parameters. It can be quickly configured by simply programming the transformer ratios or shunt sensitivity
. The various output options enable a wide range of applications: measurement and protection

MEASURING UNIT FOR DISTRIBUTION PANEL, 18-OUTLET ENERGY METER

Downloads:

cpl165

• Energy meter for 18 three-phase or single-phase circuits, measures U, I, Cos, P, W
• Current measurement from 1A to 500A via Tio mini-transformer with opening mechanism. Passage diameter: 12 to 36mm
• Ethernet connection via Modbus TCP or SNMP. Embedded web server
6 simultaneous Modbus TCP connections
Option for direct bus connection on the DIN rail
Modbus connection via RS485 option

• Application:
Energy efficiency, building management
Data center: Smart PDU, PUE (Power Usage Effectiveness) measurement
The CPL165 is a comprehensive and highly compact measurement device designed to measure electricity consumption (building management, workshops, data centers, etc.) as part of an energy efficiency initiative. The Ethernet connection enables monitoring of measurements while ensuring quick and easy integration into the existing network. The internal bus allows multiple modules to be connected via a single Ethernet link. The product can be used independently on either a three-phase or single-phase network.

MEASURING STATION: WATT METER, THREE-PHASE ENERGY METER

Downloads:

cpl105


• Three-phase or single-phase network, measurement of U, I, Cos, P, Q, W
• Multi-sensor: Ti, Rogowski coil
• Ethernet connection: Modbus TCP or SNMP Embedded web server
6 simultaneous Modbus TCP connections
Option for direct bus connection on the DIN rail
• RS485 Modbus connection
• 3 relay outputs
• Display: 2-line LCD with 16 characters per line
• Can be used as 3 isolated single-phase meters
The CPL105 is primarily designed for power and energy measurement in electrical management applications
(building and workshop management, etc.), and the Ethernet connection allows for monitoring of measurements while
ensuring quick and easy integration into the existing network. The internal bus allows multiple modules to be consolidated onto a single Ethernet connection.

WATT METER, ENERGY METER FOR UNBALANCED THREE-PHASE NETWORKS

Downloads:

cpl101


Electrical Measurement Transmitter • Unbalanced three-phase network with or without neutral, frequency from 40 to 400 Hz.
• Programmable: functions: voltmeter, ammeter, frequency meter, wattmeter, varmeter, power factor, power factor (Cos phi)
• Up to 3 analog outputs: 0…4…20 mA, 0…10V, +/- 20mA, +/-10V
• 1 relay output usable for energy metering or as a threshold relay
• CPL101/C: RS485 MODBUS connection option
• CPL101T: High-speed version (response: 100 ms)

The CPL101 is a programmable transmitter designed to measure electrical network parameters.
It supports all network wiring configurations commonly found in industry. Equipped with a wide range
of outputs, it can be used as an analyzer, converter, energy meter, controller, or protective device.

ALTERNATING VOLTAGE AND CURRENT CONDITIONER POWERED BY THE 4..20 MA LOOP

Downloads:

cal45ca

• Measurement of sinusoidal alternating signals (voltage or current)

• Direct input up to 250A and 1000V
• Galvanic isolation (up to 5000V)
• Accuracy: +/- 0.5%
• CAL45CA: measures 5A AC/DC; 500V AC/DC
• CAL45CAD: measures up to 50A AC; 1000Vac

The CAL45CA family of measurement converters converts AC voltages or currents (
) into a 4–20 mA current proportional to the input value. The use of 2-wire technology (
, where the converter is powered by the 4–20 mA loop) simplifies wiring.

DC CONVERTER

Downloads:

cal35cc

• DC input from 1 A to 100 A (or ±1 A to ±100 A)
; bandwidth up to 50 kHz

• Hall-effect technology with 25 mm² screw terminal input (5 A to 100 A max.)

• Single- or dual-pole current or voltage output: 0–4–20 mA, ±20 mA, ±10 V,
, isolated from the power supply

• Direct shunt replacement possible Isolated mV output (no heat dissipation)

Power supply
: 4.5–18 Vdc, 18–36 Vdc, 9–36 Vdc, 18–75 Vdc, …

The CAL35CC transmitter measures DC current up to 100 amps, serving as an effective replacement for measuring shunts by reducing insertion losses and providing a conditioned signal (4–20 mA, 0–10 V, or mV). The open-frame version is particularly suitable for retrofitting existing installations and even allows for installation without shutting down the system.
Applications: solar farms, wind farms, batteries, industry
– detection of defective panels
– measurement of power output from each panel
– control of panel orientation
– battery monitoring, DC motor monitoring
– welding

ALTERNATING CURRENT AND VOLTAGE CONDITIONER

Downloads:

cal35cad

• CAL35CAD
Measurement of sinusoidal AC signals

• CAL35CAD-RMS (true RMS version)
, PWM, phase angle modulation,
,
, and all signals with high harmonic content

• Built-in through-hole Ti option rated up to 50Aac


The CAL35CAD measures AC voltage or current and converts it into a standardized analog signal (0 … 4 … 20 mA or 0–10 V) proportional to the rms value of the input signal.
Using the built-in current-sensing transformer (optional) allows for direct measurement without an external transformer.

MEASUREMENT TRANSMITTER FOR RMS (AC) OR TRMS (AC+DC) CURRENT AND VOLTAGE

Downloads:

cal35ca

Measurement converter for 50 Hz, 60 Hz, and 400 Hz sinusoidal AC signals (voltage or current) (
)

• CAL35CA/A version powered by the measurement signal

• CAL35RMS true RMS version (AC)
DC component suppression
all signals up to 500 kHz
PWM – PWM, Pulse train,
Phase angle modulation

• CAL35TRMS
TRMS measurement (AC+DC)
all signals up to 500 kHz

The CAL35CA family of measurement converters converts AC voltages or currents (